Filter Results By:

Products

Applications

Manufacturers

Showing results: 541 - 555 of 674 items found.

  • Trace Level Chemiluminescence NO-NOy Analyzer

    Model T200U NOY - Teledyne Advanced Pollution Instrumentation

    The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.

  • Trace-Level Chemiluminescence NO/NO2/NOx Analyzer

    Model T200U - Teledyne Advanced Pollution Instrumentation

    The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.

  • RF Spectrum Power Meter

    SPM-50 - ShinewayTech

    SPM-50A Spectrum Power Meter brings innovative testing concept and approach for RF cable system installation and maintenance. It combines the key function of spectrum analyzer and power meter, designed to measure the power characteristics of particular signal among mixed signals transmitted on cable, fast and accurately present result in power histogram or spectrum chart.

  • Digital MCA Tube Base For Gamma-Ray Spectroscopy

    Gamma Stream Family - CAEN S.p.A.

    CAEN Gamma stream is a compact and portable system for gamma ray spectroscopy with scintillation detectors, which provides an active Multi-Channel Analyzer (MCA) integrated in a 14-pin photo-multiplier tube (PMT) base. Gamma stream fully integrates in a stand-alone device the high voltage to bias the PMT, the preamplifier to shape the signal from detector, and the MCA for a complete Pulse Height Analysis online.

  • EPM-P Series Dual-Channel Power Meter

    E4417A - Keysight Technologies

    20 M sample/s per second sampling rate for reliable continuous and single shot measurements on wide bandwidth signals Time-gated and free run power measurements Free Analyzer Software software for complete pulse and statistical analysis, software is located In the Library8 pre-defined wireless configurations (GSM, EDGE, NADC, iDEN, Bluetooth, IS-95 CDMA, W-CDMA and cdma 2000)

  • Field Analyzers

    EMC Test Design, LLC

    Active broadband isotropic antenna combined with portable USB powered spectrum analyzer. OFA-S/SE antenna has frequency response independent of antenna or electric field orientation. It offers broad dynamic range for the variety of RF regulatory, safety, EMC, wireless and telecommunications applications. Spectrum analyzer SA-S displays the frequencies and field strength of selected signals, allowing all results to be viewed and stored on PC.

  • Selective Field Analyzer

    SFA-S - EMC Test Design, LLC

    Active broadband isotropic antenna combined with portable USB powered spectrum analyzer. OFA-S/SE antenna has frequency response independent of antenna or electric field orientation. It offers broad dynamic range for the variety of RF regulatory, safety, EMC, wireless and telecommunications applications. Spectrum analyzer SA-S displays the frequencies and field strength of selected signals, allowing all results to be viewed and stored on PC.

  • Keysight Quad 1x4 75 Ohm 1.5 GHz Multiplexer Module for 34980A

    34942A - Keysight Technologies

    The Keysight 34942A RF multiplexer module for the 34980A Multifunction Switch/Measure Unit offers bi-directional switching broadband signals. High channel isolation ensures quality dynamic range measurements with your oscilloscope, spectrum analyzer, or other instrumentation.

  • BGA Interposer, LPDDR4 200-ball, 2-wing For Logic Analyzer, Connects To 61-pin ZIF

    W6601A - Keysight Technologies

    The W6601A LPDDR4 2-wing BGA interposer for LPDDR4 200-ball BGA DRAM probing takes full advantage of the quad sample state mode on the U4164A logic analyzer module it is compatible with. The W6601A is the smallest BGA interposer for LPDDR4 200-ball DRAM capable of capturing simultaneous read and write traffic at data rates in excess of 3.2 Gb/s. U4208A and U4209A probe/cables connect W6601A LPDDR4 BGA interposer directly into the U4164A logic analyzer module from 61-pin high density zero insertion force (ZIF) connectors that attach to the W6601A BGA interposer wings. Refer to the W6601A data sheet for complete list of LPDDR4 signals probed with the W6601A.

  • Single-ended, Direct Connect Probe, 34-Channel, 4 X 160-pin

    U4206A - Keysight Technologies

    The U4206A is a direct-connect probe/cable with a standard soft touch pro connector at one end that routes to four 160-pin connectors that plug into the front panel connectors of a U4164A logic analyzer module. The U4206A is designed to be used with either the quad state mode or ¼ channel 10 GHz timing mode of the U4164A logic analyzer module. For use in quad state mode only, the U4206A includes two flying leads to connect additional clock qualifier signals into the clock inputs on Pods 3 and 7. Please refer to the U4164A installation guide for specific details on the operation of the U4164A quad sample state or ¼ channel 10 GHz timing modes of operation.

  • Stand-alone Software

    N4391AU - Keysight Technologies

    The analysis software from the N4391A optical modulation analyzer can be used on your PC without any instrumentation. It offers all the analysis capabilities of the N4391A including its advanced signal processing algorithms for complex modulated optical signals. Use this software to process and analyze raw data stored as .sdf, .mat or .csv files from N4391A or N4392A measurements. This capability allows you to work with the data as if you would work directly in front of the instrument. It is an excellent tool for developing your own signal processing algorithms and testing them off-line, together with your MATLAB compiler. In addition, this software is an effective tool for learning basic and advanced concepts of complex optical modulation, based on stored files.

  • 2 GHz Dual 1:4 RF Mux, 75 Ohm Module for 34970A/34972A

    34906A - Keysight Technologies

    The Keysight 34906A RF multiplexer module for the 34970A/34972A Data Acquisition/Switch Unit offers broadband switching capabilities for high-frequency and pulsed signals. Use it to route test signals between your device under test and your signal generator, oscilloscope, spectrum analyzer, or other instrumentation. The RF multiplexers are arranged as two independent 1 x 4 multiplexers, each with a common shield and a switched center conductor. Connections can be made directly to SMB inputs with 2 GHz usable bandwidth, or to the BNC-to-SMB adapters provided with 1 bandwidth. Multiple banks may be cascaded together for applications requiring even larger topologies--create a stubless 16:1 multiplexer in a single frame.

  • Low Cost Emulator

    EB-XAS3 - Ceibo Inc.

    * Emulates P51XAS3x Microcontrollers * Real-Time Operation up to 30MHz * 3.3V or 5V Voltage Operation * Source-Level Debugger for C and Assembler * MS-Windows Debugger Software * Reduced Set of C-Compiler and Assembler * Support for ROMless and ROMed Microcontrollers * 64K of Code Memory * Performance Analyzer * Real-Time and Conditional Breakpoints * 68-pin PLCC Emulation Header and Signal Testpoints * Serially Linked to IBM PC at 115 Kbaud

  • Low Cost Emulator

    EB-XAG49 - Ceibo Inc.

    * Emulates P51XG49 Microcontrollers * Real-Time Operation up to 30MHz * 3.3V or 5V Voltage Operation * Source-Level Debugger for C and Assembler * MS-Windows Debugger Software * Reduced Set of C-Compiler and Assembler * Support for ROMless and ROMed Microcontrollers * 64K of Code Memory * Performance Analyzer * Real-Time and Conditional Breakpoints * 44-pin PLCC Emulation Header and Signal Testpoints * Serially Linked to IBM PC at 115 Kbaud

  • EMI Test Receivers

    Rohde & Schwarz GmbH & Co. KG

    EMI test receivers; extremely accurate instruments designed to detect electromagnetic emissions rigorously, to ensure all emissions conform to the Standard being tested to. Configured to set up running the required tests for parameters defined by the Standards as simply as possible, including automated test routines. R&S EMI test receivers can be much more too, with a full signal and spectrum analyzer in the same instrument.

Get Help